RAID Groups¶
Creating a RAID Group¶
VPSA RAID Groups define the level of protection against disk failure of the Pools and Volumes which contain the user’s data. Careful consideration must be given when selecting the RAID level, along with the number and type of drives, in order to avoid potential impact on performance of your data. RAID groups always span across drives from different Storage Nodes, thus a RAID Group is resilient to both a single drive failure, as well as to a complete Storage Node failure.
To create your RAID Groups first select the Drives entity in the Main Navigation Panel (Left Panel) and then click the Create RAID Group button in the Center Panel.
Define the following attributes in the “Create RAID Group” dialog box:
Enter the RAID Group name (you will later add it to a Pool so you may want to provide a meaningful name that describes the target usage of the Pool).
Note
Objects names can be up to 128 chars long and can contain letters and digits, dashes “-” and underscores “_”
Select Protection Type. Refer to the table below for a description of the various RAID levels.
Select whether to allocate a drive as a Hot Spare for this RAID group. Adding Spare drive for RAID-1 groups is recommended. See Understanding Hot Spare Drives for more details about managing Hot Spares.
Select the drives that will participate in the RAID Group. As noted in the table below, for RAID-1 a minimum of 2 drives is required.
For maximum redundancy drives MUST be selected from different Storage Nodes so the VPSA will prevent you from doing otherwise.
It is possible but not recommended to mix drives of different types in a single RAID Group.
Note
RAID-5 is no longer supported.
From zStorage version 23.09, the system does not allow RAID-6 RAID Group creation and RAID-60 Storage Pools, respectively. VPSAs that are currently using RAID-60 Storage Pools can be upgraded to version 23.09, and will also support storage expansions. For more information, contact https://support.zadarastorage.com.
Understanding RAID levels¶
The following RAID levels are supported:
RAID level |
Description |
---|---|
RAID-1 (Mirroring) |
RAID-1 mirrors the contents of one hard drive in the group onto another. If either hard drive fails, the other hard drive takes over and normal system operations are not interrupted. RAID-1, or Drive Mirroring, creates fault tolerance by storing duplicate sets of data on a minimum of two hard drives, and offers an excellent combination of data protection and performance. There must be 2 or 3 drives in a RAID-1 group. RAID-1 and RAID-10 are the most costly fault tolerance methods because they require 50 percent of the total combined drives capacity to store the redundant data. |
RAID-10 (Mirroring and Striping) |
RAID-10, or Drive Mirroring and Striping, is achieved in a VPSA by creating RAID-1 RAID Groups and striping them together at the Pool level. RAID-10 first mirrors each drive in the array to another, and then stripes the data across the mirrored pair. If a physical drive fails the mirror drive takes over and normal system operations are not interrupted. RAID 10 can withstand multiple simultaneous drive failures, as long as the failed drives are not mirrored to each other. RAID-10 creates fault tolerance by storing duplicate sets of data on a minimum of four hard drives and offers the best combination of data protection and performance. RAID-10 is the most costly fault tolerance method because it requires 50 percent of the total combined drives capacity to store the redundant data. |
Deleting a RAID Group¶
The VPSA administrator can delete delete a specific RAID Group if it not needed by clicking the Delete option under the RAID Group’s top option menu.
Note
A RAID Group can be deleted in case it is not allocated to a storage pool The system will block deletion of alloacted RAID groups.
Viewing RAID Group properties¶
The RAID-Group’s details (properties and metering), are shown in the South Panel tabs:
Properties
Each RAID Group includes the following properties:
Property |
Description |
---|---|
ID |
An internally assigned unique ID. |
Name |
User assigned name. Can be modified anytime. |
Comment |
User free text comment. Can be used for labels, reminders or any other purpose |
Protection |
Selected RAID level - RAID-1. |
Capacity |
Total protected and usable capacity of the RAID Group. |
Available Capacity |
The RAID Group’s usable capacity that is not allocated to any Pool. |
Mirror Number |
Number of mirror copies for RAID-1. |
Status |
|
Created |
Date & time when the object was created. |
Modified |
Date & time when the object was last modified. |
Drives
Lists the disk Drives participating in the selected RAID Group. The following information is displayed per drive:
Name
Capacity (in GB)
Location (Storage Node)
Type (SAS/SATA/SSD/TBD)
Status (Normal/Failed/TBD)
Hot Spare (Yes/No)
Metering
The Metering Charts provide live metering of the IO workload associated with the selected RAID Group.
The charts display the metering data as it was captured in the past 20 intervals. An interval length can be one of the following: 1 second, 10 Seconds, 1 minute, 10 minutes, or 1 hour. The Auto button lets you see continuously-updating live metering info.
Note
The metering info of the RAID Group doesn’t include RAID-generated IOs, such as when doing a rebuild.
The following charts are displayed:
Chart |
Description |
---|---|
IOPs |
The number of read and write commands issued to the RAID Group per second. |
Bandwidth (MB\s) |
Total throughput (in MB) of read and write SCSI commands issued to the RAID Group per second. |
IO Time (ms) |
Average response time of all read and write SCSI commands issued to the RAID Group per selected interval. |
Logs
Displays all event logs associated with this RAID Group.
Understanding Hot Spare Drives¶
When creating a RAID Group, you can decide whether you’d like to allocate hot spare drives to the RAID Group or not. You can change this selection at any time by clicking the Add Spare or Remove Spare buttons on a selected RAID Group in the VPSA GUI’s RAID Groups page.
Allocating a hot spare drive for a RAID Group allows for immediate and automated drive replacement, with no human intervention, once the VPSA determines that the drive has failed.
If you choose not to allocate a hot spare drive to your RAID group, you can still replace a failed drive with any available drive that is not used in any other RAID Group within the VPSA. You can execute this process manually, or automate it via the VPSA REST APIs. Simply identify and select the failed drive, click the Replace button and select the available drive to use for the replacement. For more details see Replacing a Drive.
Managing RAID Group Sync Speed¶
The RAID Group Sync Speed button allows you to control the rate with which data is synchronized during a RAID rebuild process on both a newly created RAID group and following a drive replacement.
Setting the Sync Speed is a tradeoff between the need to complete the RAID rebuild as quickly as possible in order to return to full redundancy level and the ability to supply good response time and throughput for application IOs. Therefore, the VPSA allows you to control two parameters impacting the sync Speed:
“Max Speed During Host I/Os” – Controls the RAID sync speed when there are Server IOs. You will want to set it low if the Server’s IOs are the priority. Set it high if you want to prioritize the RAID rebuild process.
Default value: 10 MB/s
Range: 1 - 500 MB/s
“Max Speed w/o Host I/Os” – Controls the sync speed when there are no Server IOs. You would typically set it to max value (500 MB/s), unless it consumes too much of the VPSA’s resources (depending on the Engine type) which impacts the performance of other RAID Groups (which do have active Server IOs).
You can set and modify Sync Speed at any time, and it can vary between RAID groups. The Sync Speed also applies to Media Scan.